Who's Online
There currently are 5849 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Thank you for your manual It has the basic things to and i use the Oszi for Longer Time.
THX
;
Actually, I was looking for this information for 3 years!...now thanks to you, the manual is on my hands and of great help, cause I understand now where I was doing wrong connections and wires...excellent, I'll be back to you if in need, thank you.
;
This manual covers the main equipment features only. While it also includes the procedure for saving and loading from the now long obsolete memory cards it does not mention the how to operate with the optional floppy drive interface so I am still at a loss about how to use this! Note that there is a separate manual covering the MIDI interface and programming via the keyboard, not included in this download. You will also need to get hold of this if you want to use the MIDI interface properly. Basically there is little difference between this manual and the free to download manual for the similar PR60 model.
;
Good list of manuals. I found a very rare one and easily get. Should be promptly to download, as we must to wait hours even after confirmed payment.
;
The manual was properly scanned and perfectly readable. The only small problem is that I couldn't use my dear Ctrl + F to find a word I needed.
Ic
Product Damage DO NOT connect to a hot water supply line. Failure to follow this instruction could result in product damage. Take note of water requirements listed under . the Use & Care section of this booklet. The filtration system�s feed line (orange tubing) connects to your cold water supply line using the saddle valve. Do not use saddle valve if it is prohibited by your state or local plumbing codes. The saddle valve is for use with 3/s� to s/B�outer diameter (O.D.), soft copper pipe (plain or chrome plated) or rigid metal or plastic pipe. Important: DO NOT use the saddle valve on flexible ribbed tubing. The wall thickness of flexible ribbed tubing is thin and will not support the saddle valve supplied. If your cold water supply is connected to the cold water faucet with flexible ribbed tubing, contact your local plumbing supply distributor to obtain special connecting hardware. Important: If local codes do not permit the use of saddle valves, special feed valves can be obtained from your local plumbing supply distributor. Use only W� polyethylene tubing for water line connection.--
Connect saddle valve to cold water supply . soft copper pipe. Check that saddle valve piercing lance does not protrude beyond rubber gasket. If it is protruding, carefully push it in flush with the rubber gasket, using a hard object like the end of a screwdriver handle.
ji 1 li *
i
la
Connect saddle valve to cold water supply . rigid metal or plastic pipe. Use a grounded electric drill or a hand drill to drill 3h6� hole in top side c of horizontal pipe or side of vertical pipe. This will keep sediment from �collecting in valve. Turn saddle valve handle clockwise to expose piercing lance a maximum of %6� beyond the rubber gasket. Align piercing lance over hole you drilled in pipe. Then assemble saddle valve on pipe with large �U� side against pipe. Tighten bottom screw firmly, . keeping bracket parallel to pipe Turn saddle valve handle clockwise until oiercina lance enters hole in pipe and then stops. The saddle valve is now in the closed position.
Ih
5
II
�
pipe installation pipe installation
Id
le
Assemble saddle valve on copper pipe. . Saddle valve must be on top side of horizontal pipe or side of vertical pipe to keep sediment from collecting in its valve. If you are connecting the saddle valve to 3/e� O.D. copper pipe, assemble bracket with small �U� side against copper pipe to prevent distortion of pipe. If you are connecting the saddle valve to %6� to W O.D. pipe, assemble bracket with large �U� side against copper pipe. Tighten bottom screw firmly. DO NOT . over-tighten; copper pipe could be crushed.
Have a towel ready in case of 11 . leaks. Turn on cold water supply to check for leaks. In case of leaks, use an adjustable wrench to tighten nut below valve�s handle. Turn cold water back off.
n
Ik
Property/Product Damage DO NOT install tubing in an area where temperatures drop below 32°F. DO NOT overtighten saddle valve to copper pipe. This will crush pipe. Keep a bucket or towel under area where saddle valve connection is made. Failure to follow these instructions may result in water damage to property or product damage.
l l l
Remove cover from filtration . assembly by lifting straight up. screw _ Move filtration assembly near area wnere it will SkeVe be mounted - either under sink or in the basement. For best results, locate filtration assembly so tubing can be cut to shortest length possible. To connect one
Ll
nk
screw
If
Have a towel ready in case of leakage. Turn . saddle valve handle clockwise until the lance pierces soft copper pipe and then stops. Do not
lb
Turn off cold water SUDDIV. Turn on cold . water faucet and allow all water to drain from line. Turn off faucet. Determine if your cold water supply line is soft copper pipe or rigid metal or plastic pipe. If your cold water supply line is soft copper pipe, proceed to step 1c. If your cold water supply line is rigid metal or plastic pipe, skip ahead to step 1h.
continue to turn the saddle valve handle after it has stopped because you may pierce through the opposite side of pipe. The saddle valve is now in the closed position. Turn on cold water supply to check for Ig . leaks. In case of leaks, use an adjustable wrench to tighten nut below valve�s handle. Turn cold water back off and proceed to step 1k.
end of orange tubing to the saddle valve, place the brass compression nut on the orange tubing (threaded side out) place the plastic sleeve onto the tubing (discard brass sleeve), push the insert into the tubing and thread this assembly onto the opening of the saddle valve. Tighten brass compression nut with %� wrench Use a plastic tubing cutter or sharp razor knife to cut tubing to shortest possible length. Make sure cut end is clean and blunt and tubing is round. Push free end of orange tubing as far as it will go into the grey push-in fitting on the front right side of 3:; the filtration assembly.
|
|
|
> |
|