Who's Online
There currently are 5954 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
The manual was complete and of great quality. Originally a tri-lingual file, I first received only one language. After a note to owners-manuals.com, I quickly received the remaining languages... Great service, definitely worth it.
;
Thank you for providing this manual and at low cost.
The Philips scope is of excellent quality, longevity and build and had a couple of faults
when it was passed to me. Having the CCT diagrams is a blessing.
I have fixed the problems and also modded the scope to my requirements.
I have built a 24v Li-Ion pack for portable use from old but good laptop batts.
it is working beautifully and I am well pleased. Keep up the good work Guys.
;
manual was very helpful in learning how to propery use my washer. I could not find this manual anywhere else.
;
Awesome quality manual. You really saved my bacon with this one. Was looking for some specific information with regards to my "new" vintage VCR that didn't come with the owners manual. This site is truely a goldmine of available manuals. The quality of the scans are top notch.
Thank-you so much for this awesome manual. If you're looking for this Sony SL-HF400 owners manual, this is the one you NEED to buy. Definitely worth the money.
;
The manual was made available promptly. I is a clean scan of the original. I had no problem downloading it. The scan was well centered and cleanly formatted. It is as good a product as can be had without being the original document.
PL12-Program Location
Enter Amount for Additional Time This location determines the amount needed to add more time to a dry cycle. The amount for additional time is programmable from a minimum of 0.05 to a maximum of 25.00 adjustable in 0.01 increments.
PL13-Program Location
Enter Prepurge Time 0 to 25-seconds When the Phase 7 controller detects the need for heat, it will wait for this prepurge time to expire before actually sending the signal for the heat to turn on. Enter DSI Purge Time 0 to 25-seconds After the controller sends the heat signal, the controller will wait for the direct spark ignition (DSI) purge time to expire before it checks to see if the gas valve return signal is present. Enter DSI Proof Time 0 to 20-seconds After the controller receives a gas valve signal within the DSI purge time, the controller will begin a DSI proof timer. After the DSI proof time has expired, the controller will recheck for the gas signal. Enter Buzz Time 1 to 9 beeps If the buzzer mode is set to �ON�, this location determines how many times the buzzer will beep at the end of an Anti-Wrinkle cycle. Enter Pause Time 0 to 3 minutes If the pause button is pressed and the main door is open, the controller will wait for the pause time defined in this setting to expire. Once the time has expired, the controller will begin to count down the dry time. If the pause button is not pressed prior to opening the door, the controller will not wait for the pause time before counting down the dry time.
PL14-Program Location
Enter Lint Cleaning Frequency 0 to 10 hours This feature monitors the hours of drying time and compares it with the Lint Cleaning Frequency setting in PL14. Once the lint cleaning frequency time has been met, the controller will begin prompting the user to clean the lint drawer. The controller will allow two (2) more hours of drying time before locking out the controller. The controller will not respond until after the lint drawer has been cleaned out. When the lint drawer is opened, the display will read �LINT ACCESS OPEN,� and when the lint drawer is closed, the controller will go back to a ready state and will read �Ready, Insert 25¢ to Start� (NOTE: The lint access must be opened for 5-seconds or more for the reset to occur). Enter Retry Count 0 to 2 This count is used to determine how many ignition attempts are allowed if an ignition attempt is unsuccessful. This counter increments when the heat output engages and the valve signal is lost after the trial for ignition period expires. This counter also will automatically reset once an ignition attempt is successful. The retry count range is from 0 to 2.