Who's Online
There currently are 5838 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Thank´s for your help, I already recived these manual from you
;
Thank you for your manual It has the basic things to and i use the Oszi for Longer Time.
THX
;
Actually, I was looking for this information for 3 years!...now thanks to you, the manual is on my hands and of great help, cause I understand now where I was doing wrong connections and wires...excellent, I'll be back to you if in need, thank you.
;
This manual covers the main equipment features only. While it also includes the procedure for saving and loading from the now long obsolete memory cards it does not mention the how to operate with the optional floppy drive interface so I am still at a loss about how to use this! Note that there is a separate manual covering the MIDI interface and programming via the keyboard, not included in this download. You will also need to get hold of this if you want to use the MIDI interface properly. Basically there is little difference between this manual and the free to download manual for the similar PR60 model.
;
Good list of manuals. I found a very rare one and easily get. Should be promptly to download, as we must to wait hours even after confirmed payment.
Troubleshooting
Beforeyou call for service . . .
If you are having an operating problem, check the chart to see what the cause might be before you call for assistance. PROBLEM Unit won�t run.
l
CHECK IF Power cord is plugged into a live circuit with proper voltage. Fuse has blown or circuit breaker has tripped. Also, check if a time-delay fuse has been used. System Control is set to OFF. Local power has failed. Time-delay fuse being used is of correct capacity. An extension cord is being used. Cooling circuit was turned off and on again quickly. Filter is dirty. Inside evaporator coils and outside condenser coils are dirty. There is excessive heat or moisture in room.
l
WHAT TO DO Firmly plug power cord into electrical outlet. Check circuit voltage at fuse/circuit breaker box. Replace fuse with a time-delay fuse of the correct capacity. Reset circuit breaker. Set System Control to another setting. Wait for power to be restored. Replace fuse with a time-delay fuse of the correct capacity. Do not use an extension cord with this or any other appliance. Wait at least 3 minutes after turning cooling circuit off before trying to restart unit. Clean filter. (See page 5.) Clean coils. (See page 6.) Use exhaust fans to reduce room heat, or set Exhaust Control to CLOSED to reduce moisture. Set System Control to a higher setting. Set Thermostat Control to a higher number.
l
l
l
l
l
l
Unit blows fuses or trips circuit breaker.
l l
l l
l
l
Unit turns on and off, or does not cool room.
l l
l l
l
l
l
Fan speed is too low. Thermostat setting is too low.
l
l
l
Normal operating sounds . . .
When your room air conditioner is operating normally, you will hear sounds such as: l Droplets of water hitting the condenser, causing a �pinging� or �clicking� sound. Water droplets help to cool the condenser. l Air movement from the fan, especially on HI COOL setting. l �Clicks� from the cooling cycle. Sounds also may be caused by house construction - such as vibration of the unit due to wall construction or unsteady window mounting area.
|
|
|
> |
|